Choose your region and language

Global
Argentina
Australia
Austria
Bahrain
Brazil
Bulgaria
Canada
Chile
China
Colombia
Czech Republik
Denmark
Egypt and North Africa
Finland
France
Germany
Greece
Hungary
India
Indonesia
Iraq
Ireland
Italy
Japan
Jordan
Kuwait
Malaysia
Mexico
New Zealand
Norway
Oman
Pakistan
Panama
Peru
Philippines
Poland
Portugal
Qatar
Saudi Arabia
Singapore
Slovakia
South Africa
South Korea
Spain
Sweden
Switzerland
Taiwan, China
Thailand
Türkiye
Ukraine
United Arab Emirates
United Kingdom
United States
Vietnam
English
Spanish
English
German
English
Portuguese
English
English
French
Spanish
Chinese
Spanish
English
English
English
English
French
German
English
English
English
English
English
English
Italian
Japanese
English
English
English
Spanish
English
English
English
English
Spanish
Spanish
English
Polish
English
English
English
English
English
English
English
Spanish
Swedish
German
French
Italian
English
English
English
English
English
English
English
English
Go

Menu

Inductive Voltage Transformer Type SPOF (25-38 kV)

Compact and robust

SPOF outdoor rated distribution class inductive voltage transformers are of compact single-phase designs and intended for connection between phase and ground (single bushing) or phase-to-phase (two bushing design) to provide critical voltage measurement information. Hermetic sealing of the design is accomplished using a gas cushion above the oil to prevent free-breathing outside moisture-laden air.

The extremely low core flux density enables the SPOF to withstand continuous 110 percent rated voltage continuously, and provide 190 percent for 8 hours.  

The SPOF has a reputation for reliable performance in service with a low field failure rate that is lower than the industry average.
 

Applications

  • Revenue metering
  • Control
  • Indication
  • Relay protection

Why Hitachi Energy?

  • Designed for environmentally diverse conditions - polar to desert
  • Excellent application engineering support ensures optimal solutions for your project
  • Low loss distributed gap core ensures the best accuracy performance with the lowest core losses for the duration of service life
  • Small footprint, eco-efficient minimum-oil design
  • Maximum reliability and minimal maintenance 

Brief performance data

SPOF  
Installation Outdoor
Design Inductive type
Insulation Oil-paper
Highest voltage for equipment 25 - 38 kV
Voltage factor (Vf) Up to 1.9 - 8hrs
Insulators Cycloaliphatic epoxy
Creepage distance ≥ 25 mm/kV (longer by request)
Service condition  
  • Ambient temperature
-40ºC to +40ºC (standard)
  • Design altitude
Maximum 1000 m (standard)
  *Other temperatures and altitudes are possible
Accuracy Meets all IEC and IEEE metering and protection classes