Escolha a sua região e idioma

Global
Argentina
Australia
Austria
Bahrain
Brazil
Bulgaria
Canada
Chile
China
Colombia
Czech Republik
Denmark
Egypt and North Africa
Finland
France
Germany
Greece
Hungary
India
Indonesia
Iraq
Ireland
Italy
Japan
Jordan
Kuwait
Malaysia
Mexico
New Zealand
Norway
Oman
Pakistan
Panama
Peru
Philippines
Poland
Portugal
Qatar
Saudi Arabia
Singapore
Slovakia
South Africa
South Korea
Spain
Sweden
Switzerland
Taiwan, China
Thailand
Türkiye
Ukraine
United Arab Emirates
United Kingdom
United States
Vietnam
English
Spanish
English
German
English
Portuguese
English
English
French
Spanish
Chinese
Spanish
English
English
English
English
French
German
English
English
English
English
English
English
Italian
Japanese
English
English
English
Spanish
English
English
English
English
Spanish
Spanish
English
Polish
English
English
English
English
English
English
English
Spanish
Swedish
German
French
Italian
English
English
English
English
English
English
English
English
Ir

Menu

Voltage limiting device HVL

Voltage limiting device for DC traction systems

Voltage limiting device HVL consists of the parallel connection of a metal-oxide (MO) surge arrester with no spark gaps and two anti-parallel connected thyristors. Transient surges caused by lightning and switching operations in the system are limited by the MO arrester. If surges occur for a longer period of time (milliseconds to hours) due to faults in the system or for operational reasons, the thyristors fire to limit touch voltages. As soon as a zero-current transition occurs, the thyristors cut off the current flow and the original condition is restored. The whole device is molded in silicone, designed and tested according to EN 50122-1 (IEC 62128-1), EN 50123-5 (IEC 61992-5), EN 50526-1 (IEC 62848-1).

Voltage limiting devices are used to prevent impermissible touch voltages in DC traction systems in normal operations and in fault conditions by bonding the return circuit of a DC railway system to the earthing system or to the exposed conductive parts.

Voltage limiting devices are available for nominal triggering voltage 60 V and 120 V.
 

Applications

  • HVL compiles with both VLD-O (normal operation) and VLD-F (fault) functionality in the specified current range

Why Hitachi Energy?

  • Over 100 years of experience in overvoltage protection and more than 30 years with silicone insulation
  • Local and global Hitachi Energy application support
  • Own production of metal-oxide (MO) resistors
  • Mechanically strong design
  • UV resistant  silicone housing with excellent pollution performance
  • Voltage limiting device HVL does not require power supply

Brief performance data

    HVL-60 HVL-120
Normal triggering voltage V 60 120
DC short-time withstand current at 100 ms - recoverable kA 2.1 2.1
DC short-time withstand current at 100 ms - non-recoverable kA 20 20
Discharge current (In) kA 25 25
High current impulse with wave 8/20 µs kA 80 80
High current impulse with wave 10/350 µs As 12 12

 

For more details see the data sheet in downloads below.