Choose your region and language

Global
Argentina
Australia
Austria
Bahrain
Brazil
Bulgaria
Canada
Chile
China
Colombia
Czech Republik
Denmark
Egypt and North Africa
Finland
France
Germany
Greece
Hungary
India
Indonesia
Iraq
Ireland
Italy
Japan
Jordan
Kuwait
Malaysia
Mexico
New Zealand
Norway
Oman
Pakistan
Panama
Peru
Philippines
Poland
Portugal
Qatar
Saudi Arabia
Singapore
Slovakia
South Africa
South Korea
Spain
Sweden
Switzerland
Taiwan, China
Thailand
Türkiye
Ukraine
United Arab Emirates
United Kingdom
United States
Vietnam
English
Spanish
English
German
English
Portuguese
English
English
French
Spanish
Chinese
Spanish
English
English
English
English
French
German
English
English
English
English
English
English
Italian
Japanese
English
English
English
Spanish
English
English
English
English
Spanish
Spanish
English
Polish
English
English
English
English
English
English
English
Spanish
Swedish
German
French
Italian
English
English
English
English
English
English
English
English
Go

Menu

Generator circuit-breaker HEC 7/8 for 170-210 kA

One step ahead in SF₆ technology

With short-circuit ratings from 170 to 210 kA, HEC 7/8 is suitable for power plants up to 1,600 MW and is recommended for retrofits or replacements of old generator circuit-breakers (GCBs) in air-blast technology. Naturally cooled up to 25,000 A, its interrupting technology allows to clear fault currents exhibiting very high degree of asymmetry up to 120-130 percent.

The 3-phase system includes circuit-breaker, disconnector, capacitors and control cubicle, and offers a wide selection of additional components, such as earthing and starting switches, current and voltage transformers and surge arresters. It is delivered fully assembled to minimize the installation and commissioning time at site.
 

Applications

  • Rated short-circuit current up to 210 kA for application in the largest power plants
  • Load current up to 28,000 A
  • GCB system solution for power plants up to 1,600 MW

Why Hitachi Energy?
 

  • Naturally cooled up to 25,000 A
  • With more than 300 references, HEC 7/8 secures reliable operation in power plants all around the world
  • Its state-of-the-art technology ensures safe operation and interruption of short-circuit currents up to 210 kA
  • Fully type tested according to IEEE C37.013, the worldwide GCB standard
Available options:
Product image for: Generator circuit-breaker HEC 7/8 for 170-210 kA

Brief performance data

System Type HEC 7A/8A HEC 7B/8B HEC 7C/8C
Rated maximum voltage [kV]: 30 27.5 25.2
Rated frequency [Hz] 50 / 60 50 / 60 50 / 60
Rated power frequency withstand voltage [kV] 80 80 80
Rated lightning impulse withstand voltage [kV] 150 150 150
Rated short-circuit breaking current [kA] 170 190 210
       
HEC 7/8 with 50 Hz      
Rated normal current [A]: HEC 7 up to 25,000 up to 25,000 up to 25,000
Rated normal current [A]: HEC 8 up to 28,000 up to 28,000 up to 28,000
       
HEC 7/8 with 60 Hz      
Rated normal current [A]: HEC 7 up to 22,000 up to 22,000 up to 22,000
Rated normal current [A]: HEC 8 up to 26,500 up to 26,500 up to 26,500