Choose your region and language

Global
Argentina
Australia
Austria
Bahrain
Brazil
Bulgaria
Canada
Chile
China
Colombia
Czech Republik
Denmark
Egypt and North Africa
Finland
France
Germany
Greece
Hungary
India
Indonesia
Iraq
Ireland
Italy
Japan
Jordan
Kuwait
Malaysia
Mexico
New Zealand
Norway
Oman
Pakistan
Panama
Peru
Philippines
Poland
Portugal
Qatar
Saudi Arabia
Singapore
Slovakia
South Africa
South Korea
Spain
Sweden
Switzerland
Taiwan, China
Thailand
Türkiye
Ukraine
United Arab Emirates
United Kingdom
United States
Vietnam
English
Spanish
English
German
English
Portuguese
English
English
French
Spanish
Chinese
Spanish
English
English
English
English
French
German
English
English
English
English
English
English
Italian
Japanese
English
English
English
Spanish
English
English
English
English
Spanish
Spanish
English
Polish
English
English
English
English
English
English
English
Spanish
Swedish
German
French
Italian
English
English
English
English
English
English
English
English
Go

Menu

Generator circuit-breaker HEC 9 for 250-300 kA

The world’s largest generator circuit-breaker (GCB)

HEC 9 has been developed as a system for large-sized power plants such as nuclear, coal-fired and hydropower plants. It has the world's highest performance with short-circuit currents up to 300 kA and it is also highly suitable for retrofits or replacements of old GCBs in air-blast technology.

Based on Hitachi Energy's well-proven and highly reliable SF6 technology, it enables lower lifecycle costs and gives a time-to-overhaul period of up to 20 years.

It is delivered in single-phase systems to facilitate the transportation and installation with plug-in design to minimize the activities at the site. Besides circuit-breaker, disconnector, capacitors and control cubicle, it also includes a wide selection of additional components such as earthing and starting switches, current and voltage transformers and surge arresters.
 

Applications

  • Load current up to 33,500 A
  • Power units up to 2000 MW
  • Indoor or outdoor installations
  • Replacements or retrofits of old units

Why Hitachi Energy?
 

  • Naturally cooled up to 28,500 A
  • Delivers the highest performance rates
  • Provides the lowest lifecycle costs - maximum system availability and reliability
  • Based on SF6, it is the only alternative to old and obsolete GCBs in air-blast technology
  • Fully type tested according to IEEE C37.013, the worldwide GCB standard
Available options:
Product image for: Generator circuit-breaker HEC 9 for 250-300 kA

Brief performance data

System Type HEC 9-250L HEC 9-250XL HEC 9-300L HEC 9-300XL
Rated maximum voltage [kV] 31.5 31.5 31.5 31.5
Rated frequency [Hz] 50 / 60 50 / 60 50 / 60 50 / 60
Rated power frequency withstand voltage [kV] 80 80 80 80
Rated lightning impulse withstand voltage [kV] 150 150 150 150
Rated short-circuit breaking current [kA] 250 250 300 300
         
HEC 9 with 50 Hz *)        
Rated normal current [A]: natural cooled up to 28,500
(naturally cooled)
up to 33,500
(enhanced convection)
up to 28,500
(naturally cooled)
up to 33,500
(enhanced convection)
         
HEC 9 with 60 Hz *)        
Rated normal current [A]: natural cooled up to 26,500
(naturally cooled)
up to 32,500
(enhanced convection)
up to 26,500
(naturally cooled)
up to 32,500
(enhanced convection)
*) with IPB longitudinal forced air cooling up to 57,000   up to 57,000  

Something caught your eye?

Our sales team will get in touch with you