Choose your region and language

Global
Argentina
Australia
Austria
Bahrain
Brazil
Bulgaria
Canada
Chile
China
Colombia
Czech Republik
Denmark
Egypt and North Africa
Finland
France
Germany
Greece
Hungary
India
Indonesia
Iraq
Ireland
Italy
Japan
Jordan
Kuwait
Malaysia
Mexico
New Zealand
Norway
Oman
Pakistan
Panama
Peru
Philippines
Poland
Portugal
Qatar
Saudi Arabia
Singapore
Slovakia
South Africa
South Korea
Spain
Sweden
Switzerland
Taiwan, China
Thailand
Türkiye
Ukraine
United Arab Emirates
United Kingdom
United States
Vietnam
English
Spanish
English
German
English
Portuguese
English
English
French
Spanish
Chinese
Spanish
English
English
English
English
French
German
English
English
English
English
English
English
Italian
Japanese
English
English
English
Spanish
English
English
English
English
Spanish
Spanish
English
Polish
English
English
English
English
English
English
English
Spanish
Swedish
German
French
Italian
English
English
English
English
English
English
English
English
Go

Menu

Gas-insulated switchgear ELK-04 up to 170 kV

Modular solution for reliable energy supply

The gas-insulated switchgear ELK-04 is the ideal solution for reliable energy supply up to a rated voltage of 170 kV, a rated normal current up to 4000 A, and a rated short circuit current up to 63 kA. Based on a few building blocks with standardized dimensions, its space saving and modular design offers a small footprint and easy operation at high performance ratings. The ELK-04 offers a high level of flexibility for optimizing substation layouts.
 

Applications

  • Power transmission
  • Integration of renewable power generation units to the grid
  • Offshore and onshore wind power connections

Why Hitachi Energy?

  • Compact footprint with short installation time
  • Indoor and outdoor installation
  • Monitoring, control, protection and communication features for smooth integration into digital substation systems using IEC 61850
Product image for: Gas-insulated switchgear ELK-04 up to 170 kV

Brief performance data

GIS ELK-04    
Rated voltage [kV] 145 170
Rated frequency [Hz] 50/60
Rated short-duration power-frequency withstand voltage (1 min) [kV] 275 325
Rated lightning impulse withstand voltage (1.2/50 µs) [kV] 650 750
Rated normal current – busbar / feeder [A] 3,150 4,000
Rated short circuit-breaking current [kA] 40 63
Rated short-time withstand current (up to 3 s) [kA] 40 63
Rated peak withstand current [kA] 104 164
Bay width [mm] 1,000 1,200
Ambient temperature range [°C] -30 … +40
Installation indoor / outdoor

Something caught your eye?